Safety Information

Please read the following instructions carefully before using this device. Failure to observe these safety instructions may result in injury and will release Vivosun of all liability and void all product warranties.

  1. In case of any abnormality, turn off the dehumidifier, unplug it, and contact the seller. Abnormal operation may result in unit failure, electric shock, fire, or other hazards.

  2. It is forbidden to disassemble, modify, repair, or clean internal components without authorization.

  3. To avoid the risk of fire or explosion, do not spray liquids onto the dehumidifier. Do not place flammable materials or chemicals near the unit.

  4. To prevent resin parts from melting or catching fire, do not place the dehumidifier near heating appliances.

  5. Never insert rods or objects into the openings of the dehumidifier.

  6. Remove any water collected in the tank. Accidental consumption or use of this water may cause illness or accidents.

  7. The dehumidifier must be used on a level and stable surface.

  8. Do not use this product outdoors, in direct sunlight, or expose it to weather or other elements.

  9. Do not replace the power cord without authorization, splice it, or use it in parallel with other high-power electrical devices.

  10. Do not cover the product or power cords with rugs or other fabric materials.

  11. Place the device on a flat, dry surface, maintaining at least 50 cm of clearance from surrounding objects or walls.

  12. Do not place the product on a soft, elevated, or unstable surface where it may fall or block its air intakes or exhaust.

  13. Do not clean the dehumidifier with chemical solvents such as gasoline or alcohol. Before cleaning, disconnect the power supply and use a slightly damp soft cloth. For heavy dirt, use a mild detergent.

  14. Turn off the unit and empty the water tank before moving it. Always use the handle when relocating the unit.

  15. This device may be used by children aged 8 and above, as well as individuals with reduced physical, sensory, or mental capabilities, or those lacking experience and knowledge, provided they are properly supervised or instructed on safe usage and understand the hazards involved. Children must not play with the device.

e52775b17364bd18a26ee779f4cb2cae

Risk of Fire or Explosion – This device contains a flammable refrigerant. Please follow all additional safety precautions to avoid potential hazards.

  1. Do not use any methods to accelerate the defrosting process or for cleaning other than those recommended by the manufacturer.

  2. Store the device in a room free from continuously operating ignition sources, such as open flames, gas appliances, or electric heaters.

  3. Do not pierce or burn the refrigerant tubing. Be aware that refrigerants may be odorless.

  4. Keep all ventilation openings free from obstruction.

  5. Do not drill holes into the unit.

  6. Maintenance, cleaning, and servicing must only be carried out by technicians who are properly trained and certified to handle flammable refrigerants.

  7. Dispose of the dehumidifier in accordance with federal and local regulations. Flammable refrigerants require special disposal procedures.

PRODUCT CONTENTS

Image Quantity

5f1cd050a06e96c3b029984cc8749a18

1pc

ea406977d3edfbd1b9bdd8529d4cd4f6

1pc

8f1b3b7fc341341991a6047b44053a52

1pc

0411f46e3cc7e52081765db475794065

1pc

0d60b5ca81de6d6b5086295f30c85c8c

1pc

84addeb67087ce8557ee0296626de381

1pc

83bc9648acbd6fae5a0619fbf0f86d88

1pc

5bc6e7aa049f8d6da3f98bb6967736bd

1pc

Dimensions

Size

10.8 x 7.3 x 19.0 inch (27.5x18.5x48.2 cm)

NetWeight

19.8lbs (9 kg)

Dehumidifying Capacity

32Pints / Day@95°F,90%RH

25Pints /Day @86°F,80%RH

14Pints /Day @80°F,60%RH

8Pints /Day @65°F, 60% RH

15 L / Day @35°C, 90% RH

12 L / Day @30°C, 80%RH

7 L / Day @27°C, 60% RH

4 L / Day @18°C, 60% RH

Water Tank Capacity

2 L (4.2 Pints)

Power Supply

120 V, 60Hz / 200–240 V, 50Hz (For available voltage, please refer to product label.)

Rated Input

120 W

Refrigerant

R290

Operating Temperature

41–95°F (5–35°C)

Operating Humidity

10%–99% RH

Installation

4930c793db206a7e61e8141f7deb75c8

1

Air Outlet

2

2.5mm Jack Interface

3

Air Inlet

4

Drainage Hole

5

Water Tank

Installing the Accessories

STEP 1

Insert the air outlet hood into the air outlet of the dehumidifier.

1dfdf950f66852c9c7c6f6fe72e8653e

STEP 2

Insert the air inlet hood and filter into the air inlet of the dehumidifier.

db3c1f7f696b8babe1be73f2d64cdc2f

STEP 3

Take one Exhaust Duct (Ø 130 mm) and connect it to the air outlet hood, then tighten it clockwise.

0a03a7be4e0bda27e664004ab7d14786

STEP 4

Take one Exhaust Duct (Ø 150 mm) and connect it to the air inlet hood, then tighten it clockwise.

4c65ce982b474cc7ccc5bc7d4d17badf

STEP 5

Check if the adapter, hoods, and ducts are securely installed in place.

c63c838609663c2706a31dfb61db33d5

Configuring the Air Duct

You can configure the duct according to your specific scenario.

A. In common scenarios

7ed7e6ed4027aa933bcb216284acb3cf

B. When the plants grow tall

b092babe7fa31277c4cc7e72283bbf3c

C. Configured directly in the grow tent

3371dd962d2b78aa8af2c8640491c348

Note:

  1. Ensure the exhaust duct does not have sharp bends (greater than 45°), as this may affect the dehumidifier’s performance.

  2. Inside the tent, position the exhaust duct upwards and avoid directing airflow directly onto the leaves.

df2b26042ad5475322ee9aa8544a2389

Installing the Probe

STEP 1

Insert the temperature and humidity probe into the 2.5 mm jack located above the air inlet, and ensure it is securely connected. Note: If the probe is not connected, the display will show “–”.

e7492a0c09baa895315652cc4bcc3d34

STEP 2

Place the probe in the target area and secure it firmly. Note: It is recommended to position the sensor at a height of 2 to 4 inches above the canopy.

Drainage Methods

A. Water Tank

8b7a769248f6f6e5938aa8c637039d0e

1

Remove the water tank

2

Drain the water

3

Reinstall the tank

B. Drain Pipe

Connecting the drainage pipe allows for continuous water drainage.

ce2ca5929e21a3b81812d6d18a943154

Control Panel

f4eaf9b890bfcdb5736f7bfe0bbb2ad6
Image Name Control
fb75d67e8d06fc09887a21fbd84c1b32

On/Off Button

Press to turn on.

Press and hold for 3 seconds to turn off.

320c014203b3d039600c2066a97c81f4

Mode Button

Press to switch between Manual and Auto modes.

Press and hold to exit Recipe Mode (only effective while a recipe is running)

d386b4792a3e8c5f70f58b885769bc1f

Fan Speed Button

Press to switch the fan between Standard Mode and Quiet Mode.

376875c97d55a2f143998fa57cea344f

Up Button

Press to increase the value of the current setting.

Press and hold to switch between °C and °F

237c7924673c3ac3a3267ba34ee21158

Down Button

Press to decrease the value of the current setting.

5066a520a97c069fac8ab3a218e01168

Confirm Button

Press to confirm the current operation.

Press and hold to enter the settings menu, including calibration, and mute toggle options.

Other Button Operations:

  1. Press and hold the On/Off and Up buttons to lock or unlock the device.

  2. Press and hold the On/Off and Confirm buttons to reset the device to factory settings.

5a6000089051d6b6d7c91c021b9580af

1

Operation Mode

Displays the current mode: Manual or Auto.

2

Status Icon

Indicates various device statuses, including cloud lock, tilt, full water tank, probe detection, connection status, and mute.

3

Probe Readings

Displays current probe readings, including temperature, relative humidity, and VPD.

4

Fan Speed

Displays the current fan mode: Standard or Quiet.

Note: The fan speed icon turns off when the dehumidifier is not running.

5

Error Icon

Appears when an error is detected and displays the corresponding error code.

6

Screen lock Icon

Indicates that screen operation is locked when the icon is visible.

7

Calibration Mode

The icon appears when temperature or humidity calibration is in progress.

8

Setting Mode

The icon appears when adjusting temperature or humidity settings.

Operation

Manual Mode

Press the Operation Mode button to enter mode selection. Then, press the Mode button to cycle through the available modes. When “MANUAL” appears on the screen, press the Confirm button to confirm your selection.

2af6101d27c512e00f3e6a2625412e0d

Note:

  1. When operating in MANUAL mode, press the On/Off button to pause operation. Press the button again to resume.

  2. The fan speed can be adjusted at any time.

Auto Mode

Press the Operation Mode button to enter mode selection. Then, press the Mode button repeatedly to cycle through the modes. When “Auto” appears on the screen, press the Confirm button to proceed to the humidity setting. Use the Up and Down buttons to adjust the target humidity level, then press the Confirm button again to confirm the setting.

f2c98111d0eee8c7899ce36ce73c23e7

Note:

  1. In Auto mode, the target humidity has a buffer range of ±3%.

Wi-Fi Configuration

Step 1 Download the Vivosun App

Search “VIVOSUN” in the Apple App Store or in the Google Play Store to download the Vivosun app.

7bd620dc732d96a5759078f1d695e891

Step 2 Add AeroDrain

Tap “+” to add AeroDrain, then follow the prompts in the app to complete the Wi-Fi configuration.

fd52e459e4f762a299a916bd7de59cac

Step 3 Name Your Device

After successfully connecting AeroDrain, you can rename your device.

addc8473ac28857cc8c0250996bf8dba

Troubleshooting

Problems Reasons Solutions

The dehumidifier does not work.

There is no electricity

Turn it on after connecting it toa powered socket.

The water tank is full

Drain the water from it.

Temperature and humidity probe not detected.

Reinsert or replace the temperature and humidity probe.

The dehumidifier tipped over.

Lay the device flat and allow it to rest for at least 24 hours before use.

The ambient temperature is too low or too high.

It is recommended to use the device at a temperature between 5–35°C (41–95°F).

The environmental target humidity value has been reached.

Adjust the target humidity.

The compressor must wait for 3 minutes after stopping before it can restart (system protection).

Wait for 3 minutes and check if it works.

Product displays error code: DF: Defrosting in progress

E01: Power board communication failure

E02: NTC sensor fault

E04: EC fan fault

Wait for 5 minutes to see if the issue resolves itself. If not, please contact our customer service for assistance.

The dehumidification capacity is low.

The filter is too dirty.

Clean or replace the filter.

The air inlet and/or outlet is blocked.

Clear the blockage.

The exhaust duct is severely bent.

Ensure that the duct bend does not exceed 45°.

Noise or vibration

The dehumidifier is not placed on a flat surface.

Place the dehumidifier on a hard,flat surface.

Warranty

Vivosun provides a one-year warranty against defects on the AeroDrain Dehumidifier purchased directly from us or through our authorized dealers. This policy reflects our commitment to addressing any manufacturing defects or premature breakage that may occur during normal use of our products.

Our warranty covers the replacement or refund of purchases that exhibit material defects within one year of the original purchase date. In such cases, customers may contact us to initiate the claim process. Proof of purchase will be required to verify eligibility.

This policy does not cover products that have been misused, abused, or intentionally damaged. It also excludes normal wear and tear or cosmetic defects, such as minor scratches.

Customers can rest assured that our products undergo rigorous quality testing procedures. This one-year warranty demonstrates our confidence in the durability of our products under normal use.

If any product defects are found, customers are encouraged to contact us immediately. Your satisfaction is our top priority, and we are committed to resolving any issues in a professional and timely manner.

Contents